Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Sep Sci ; 46(14): e2300117, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37246276

RESUMO

A new enantioselective open-tubular capillary electrochromatography was developed employing poly(glycidyl methacrylate) nanoparticles/ß-cyclodextrin covalent organic frameworks chemically immobilized on the inner wall of the capillary as a stationary phase. A pretreated silica-fused capillary reacted with 3-aminopropyl-trimethoxysilane followed by poly(glycidyl methacrylate) nanoparticles and ß-cyclodextrin covalent organic frameworks through a ring-opening reaction. The resulting coating layer on the capillary was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The electroosmotic flow was studied to evaluate the variation of the immobilized columns. The chiral separation performance of the fabricated capillary columns was validated by the analysis of the four racemic proton pump inhibitors including lansoprazole, pantoprazole, tenatoprazole, and omeprazole. The influences of bonding concentration, bonding time, bonding temperature, buffer type and concentration, buffer pH, and applied voltage on the enantioseparation of four proton pump inhibitors were investigated. Good enantioseparation efficiencies were achieved for all enantiomers. In the optimum conditions, the enantiomers of four proton pump inhibitors were fully resolved within 10 min with high resolutions of 9.5-13.9. The column-to-column and inter- to intra-day repeatability of the fabricated capillary columns through relative standard deviation were found better than 9.54%, exhibiting satisfactory stability and repeatability of the fabricated capillary columns.

2.
Electrophoresis ; 43(13-14): 1446-1454, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35353923

RESUMO

In this work, a new open-tubular capillary electrochromatography (OT-CEC) column was prepared using ß-cyclodextrin covalent organic framework (ß-CD COF) as a stationary phase. Polydopamine was used to assist fabrication of ß-CD COF on an inner wall of a fused-silica capillary. The coating layer on the capillary was characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). Electroosmotic flow (EOF) was also studied to evaluate the variation of the inner wall of immobilized columns. Furthermore, the chiral separation effectiveness of the fabricated capillary column was evaluated by CEC using enantiomers of several related proton pump inhibitors as model analytes, including omeprazole, lansoprazole, pantoprazole and tenatoprazole. The effects of bonding time and concentration of ß-CD COF, the type, concentration and pH of buffer, applied voltage were investigated to obtain satisfactory enantioselectivity. In the optimum conditions, the enantiomers of four analytes were resolved within 15 min with resolutions of 1.63-2.62. The relative standard deviation values for migration times and resolutions of the analytes representing intraday and interday were less than 6.75% and 4.24%, respectively. The results reveal that ß-CD COF has great potential as chiral-stationary phases for enantioseparation in CEC.


Assuntos
Eletrocromatografia Capilar , beta-Ciclodextrinas , 2-Piridinilmetilsulfinilbenzimidazóis/análise , Eletrocromatografia Capilar/métodos , Indóis , Polímeros , Estereoisomerismo , beta-Ciclodextrinas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...